Search
You can find the results of your search below.
Fulltext results:
- separation_of_2_species_with
- nstant is too similar to distinguish between both dyes in a mixture by means of standard FCS.\\ Nevertheless, the autocorrelation curves of both dyes differ in the microsecond range. ATTO655 shows pr... somerization.\\ The fluorescence lifetime of both dyes differ significantly (~1.8 ns for ATTO655 and ~1 ... s to define these filters: * If the different dyes have been measured separately, and TCPSC curves o
- calculate_and_fit_fcs_traces_with_the_fcs_script
- * **Note** that the diffusion coefficients of all dyes are temperature dependent. * FCS measurements a... e through the confocal volume. Examples for these dyes are ATTO655 or ATTO425. Also dyes with a moderate triplet contribution can be fitted with this model if... cell membrane is observed. This model is made for dyes moving within a plane, e.g. modified lipids in a
- using_the_flcs_script_for_spectral_crosstalk_removal_via_flccs
- ions between two molecules labeled with different dyes. Usually, the dyes attached to the two molecules differ in their absorption and emission properties but... abeled with both fluorophores.\\ FCCS calibration dyes are available e.g. from IBA ([[http://www.iba-lif... ally, a positive control is needed, in which both dyes are moving in a coordinated fashion.\\ Additional
- calculate_fccs_trace_with_the_grouped_fcs_script
- ions between two molecules labeled with different dyes. Usually, the dyes attached to the two molecules of interest differ in their absorption and emission pr... abeled with both fluorophores.\\ FCCS calibration dyes are available e.g. from IBA ([[http://www.iba-lif
- how_to_measure_the_instrument_response_function_irf
- /10.1088/0957-0233/27/2/027001 Pyridinium Styryl Dyes have also been used as IRF standard: Lei Li, Men... lph Jimenez, Jianhua Xu\\ Using Pyridinium Styryl Dyes as the Standards of Time-Resolved Instrument Resp
- lifetime_fitting_using_the_tcpsc_fitting_script
- c_fitting_script_Image_17.png?600 }} * If both dyes can be fitted with the same model, click "Fit All... le, it is of course meaningless, as two different dyes were fitted. * Place the mouse over the graph,
- calculate_ratiometric_single_pair_fret_distributions_using_the_pie-fret_script
- o distinguish molecules with and without acceptor dyes and to filter the events for signals without acce
- calibrate_the_confocal_volume_for_fcs_using_the_fcs_calibration_script
- te.\\ Note that the diffusion coefficients of all dyes are temperature dependent.\\ FCS measurements are
- flim_fret_calculation_for_multi_exponential_donors
- TCSPC-window, e.g. 2PE excitation with 80MHz and dyes with a lifetime above ~3ns. For explanation on th
- pattern_matching
- on raw data. This allows for separating different dyes or regions of different lifetime/decay-behavior i